Models affected:
E82, E88 (1 Series)
E46 (3 Series)
E90, E91, E92, E93 (3 Series)
E60, E61 (5 Series)
E63, E64 (6 Series)
E83 (X3)
E70 (X5)
E71 (X6)
E85, E86 (Z4)
Situation
The customer complains of poor or no air conditioning cooling. After further
diagnosis, the system is found to be low or empty of a refrigerant charge, but
when using an electronic leak detector, no leak can be found.
Before replacing parts, perform a nitrogen leak test to confirm the location of
the leak.
Cause
In some cases, an electronic leak detector is not sufficient for identifying
small leaks in the system. Electronic leak detectors can give false alarms and
can lead to an improper diagnosis of small leaks. A leak cannot be located
exactly if accessibility is impaired (in the case of the expansion valve,
evaporator or condenser).
Procedure
Always use proper eye and hand protection whenever servicing air conditioning
systems. Refer to repair manual RA 64 50... for further information.
1. Always troubleshoot and correct any faults in the IHKA/IHKR (Independent
Heating and Air Conditioning) system before proceeding further.
2. Use symptom diagnosis to determine if the system is low or empty of a
refrigerant charge (refer to SI B64 04 07).
3. If the source of the leak is difficult to detect, the evaporator and
condenser area needs to be checked further for leaks.
4. A special testing adapter set (64 5 120) has been developed, which allows
pressure testing of the air conditioning evaporator and condenser while they
are still installed in the vehicle. This prevents a lot of unnecessary
disassembly of the vehicle for diagnosis purposes.
5. In order to use this adapter set, the following auxiliary materials will be
needed:
Nitrogen (in a pressurized cylinder) obtained locally. Ensure that employees
are advised of how to handle pressurized cylinders correctly (danger of
asphyxiation). For this purpose, follow the notes and instructions in the
technical safety specifications, available from the gas supplier.
Nitrogen tank set with pressure reducer.
Refer to SI B04 24 08 for tool information.
6. If the evaporator or condenser is suspected of leaking, recover the
remaining refrigerant from the system using a BMW-approved refrigerant recovery
machine.
7. Refer to the repair manual instructions “RA 64 51 ... Leak-testing
condenser” for instructions on what adapters are needed, and the procedure for
checking the condenser for leaks while installed in the vehicle.
8. Once the proper adapters have been fitted, connect the nitrogen bottle
(
Figure 1, 1) with the pressure reducer (2) to the pressure gauge (3). Connect
the special hose (64 5 121) to the fitting on the pressure gauge and the test
adapter on the vehicle.
Note:
The testing apparatus must be leakproof.
Ambient temperature and the temperature of the vehicle must not change
significantly during the test procedure.
The vehicle must not be moved during the test period.
9. Ensure that the regulator (
Figure 2, 1) is backed off and the flow shutoff
valve (2) is closed.
10. Open the nitrogen bottle valve slowly.
11. Open the valve (2) to the full open position. Note: The valve is shown in
the closed position.
12. Apply test pressure of 10 bar (150 psi) slowly by turning the pressure
regulator (1) clockwise.
13. A pressure of 20 bar (280 psi) must not be exceeded, as this will damage
the evaporator or other system components.
14. Once the test pressure of 10 bar (150 psi) is reached, close the valve (2).
Back off the regulator and close the nitrogen bottle valve.
15. Check the leak tightness of the testing apparatus and of the connections at
the adapters.
16. Monitor the pressure over a period of two hours. Pressure should remain
constant at 10 bar (150 psi),
Figure 3.
17. Any drop in pressure indicates that there is a leak in the evaporator or
condenser, depending on which component is being tested.
18. Release the residual pressure from the line, using the pressure relief
valve.
19. Replace the evaporator or condenser as needed.
After leak testing and repair:
Retest the system using the same procedure to ensure that there are no leaks.
Release all pressure from the test hose slowly.
Replace all sealing rings before reassembly.
Evacuate and fill the system.
Courtesy of ALLDATA.