Toyota Tech Tip: Absorbed Glass Mat (AGM) Battery Information

Toyota Tech Tip: Absorbed Glass Mat (AGM) Battery Information

This TSB provides background on the differences and similarities between AGM (Absorbed-electrolyte Glass Mat) batteries used in some 2001-'08 models, including the 2003 Prius, and flooded-lead acid batteries. It also explains charging procedures performed by the GR8 Battery Diagnostic Station (SST P/N 00002-MCGR8) and its ability to charge AGM batteries at higher current levels than a standard battery charger ....

This TSB provides background on the differences and similarities between AGM (Absorbed-electrolyte Glass Mat) batteries used in some 2001-’08 models, including the 2003 Prius, and flooded-lead acid batteries. It also explains charging procedures performed by the GR8 Battery Diagnostic Station (SST P/N 00002-MCGR8) and its ability to charge AGM batteries at higher current levels than a standard battery charger.

Battery Comparison:

1. Differences between AGM and flooded lead acid batteries:

  • AGM batteries have thin, sponge-like, glass mat separators that absorb all liquid electrolytes.
  • Flooded lead acid batteries have free, liquid electrolyte all around the plates and separators.
  • Flooded lead acid batteries can easily release gas that is formed during a charge, while AGM battery life is diminished if gas is formed during charging.

2. Similarities between AGM and flooded lead acid batteries:

  • Both share the exact same lead acid chemistry.
  • Both share the same charge and discharge principles.
  • Both are safely charged by vehicle charging systems.
  • When discharged, both can be recharged at high current levels.

Battery Charging Information:

Damage to AGM batteries becomes an issue when the charge rate is not monitored and controlled by the charger (i.e., quick chargers). The performance of an AGM battery can be irreversibly reduced if the charge rate remains too high, allowing the battery to overheat and vent. Once an AGM battery loses water (venting), the glass mats will become dry, causing the battery to lose conductance, power and performance.

In most vehicle charging systems, the alternator limits the charging rate by limiting the output voltage (about 14.4V). For example, an AGM battery may be observed charging at 60A and 13.5V. As the battery recharges, the charging voltage will increase from 13.5V to approximately 14.4V (voltage will vary based on temperature, control sophistication, etc.), and the current will decrease from 60A to about 0A. The charging system voltage regulators prevent both AGM and flooded lead acid batteries from being overcharged and venting. By controlling the voltage, the charging rate (current) can be controlled.

The discontinued Special Service Tool (SST) Automatic Trickle Charger (SST P/N 00002-YA122-01) maintained a manual charging limit of 10A to accomplish a safe recharge rate for AGM batteries. This low-amp charge was low enough to prevent the AGM battery from overheating and venting since the charger had no way of monitoring battery temperature/condition.

The GR8 Battery Diagnostic Station (SST P/N 00002-MCGR8) is a customized diagnostic fast charger that monitors battery temperature/conditions and contains custom charging rates for all model batteries used for Toyota and Scion vehicles. As such, it safely charges good batteries as fast as possible to a point where they can be returned to service, and eliminates wasted charging time by quickly diagnosing bad batteries.

Based on the characteristics and performance measures of each individual battery (i.e., custom charging rate), the GR8 Battery Diagnostic Station will apply the fastest charging rate that is safe for that particular battery.

When the GR8 Battery Diagnostic Station performance measurements indicate that an AGM battery qualifies for fast-charging, it will be charged at whatever current level it will accept, but the charging voltage will be controlled so that it does not exceed 14.4V, and the battery temperature will not exceed 135° F (57° C).

When the GR8 Battery Diagnostic Station performance measurements indicate that an AGM battery does not qualify for fast-charging, the charge session will continue only if the battery qualifies for “Recovery” mode (part of which means no defects or other serious performance issues were found).

It’s recommended that all Toyota and Scion vehicle batteries be charged using the GR8 Battery Diagnostic Station.

Note: Never connect the GR8 Battery Diagnostic Station to remote battery terminals; always connect the GR8 Battery Diagnostic Station directly to the vehicle battery.

Courtesy of IDENTIFIX.

For additional tech tips, visit www.identifix.com.

You May Also Like

Eaton to Supply ELocker Differential System to EV Manufacturer

The system leverages an electric motor to power the rear wheels and an electric motor or an optional ICE driving the front wheels.

Intelligent power management company Eaton announced it has been selected by a leading manufacturer of electrified vehicles to "supply a unique ELocker differential system for use on a new plug-in electric hybrid (PHEV) SUV."

Unlike traditional PHEVs, which use an electric motor and internal combustion engine to power all the drive wheels, the new model leverages an electric motor to power the rear wheels and an electric motor or an optional internal combustion engine (ICE) driving the front wheels, the company said.

Servicing EVs in Your Shop

Technicians need to learn how to correctly diagnose and repair electrical systems.

technician using laptop
Tool Time Podcast: Schrader TPMS

In this episode, Nadine and Eric sit down with Yanick Leduc to discuss all the TPMS solutions his company has to offer.

Eli Opens Reservations for its Micro-EV in the US

The new Eli ZERO represents a new category of high-tech, efficient and sustainable micro-EVs, according to Eli Electric Vehicles.

Hunter Engineering Releases New Alignment Coverage

Semi-annual specification update includes new and existing records.

Other Posts

#11 LED Work Lights

Light emitting diodes (LEDs) were a revolutionary development of electrical science.

LED Work Lights Feature
Eaton Receives 2024 Automotive News PACEpilot Award

Eaton was recognized for its 4-speed electrified vehicle transmission.

#10 Wire Strippers/Crimpers

Take a look at the multi-faceted world of wire strippers and crimpers.

Wire Strippers
The Autel IA900