Tech Tip: Curing Nissan Blower Motor Noise

Tech Tip: Curing Nissan Blower Motor Noise

If a customer indicates that a light ticking or humming noise can be heard coming from the blower motor (see affected vehicles) when the motor is run at low fan speeds (speed 1 or 2), a noise-reducing blower motor is available. The noise may be very slight and, at times, difficult to hear.

If a customer indicates that a light ticking or humming noise can be heard coming from the blower motor (see affected vehicles) when the motor is run at low fan speeds (speed 1 or 2), a noise-reducing blower motor is available. The noise may be very slight and, at times, difficult to hear.

Affected Vehicles:
• 1996-2001 Pathfinder (R50);
• 1995-’99 Maxima (A32);
• 2000-’01 Maxima (A33) with automatic heater/air conditioner controls.

Service Procedure:
1. Run the blower motor at low fan speed (speed 1 or 2) and evaluate the noise. Decide which category the noise falls under:

  • Loud rattle, clatter, jolt or flap: go to the procedure for blower case cleaning.
  • Light ticking or humming noise: complete the following steps to install a new blower motor cover.

2. Remove the instrument panel lower cover (if equipped).
3. Disconnect the blower motor harness connector.
4. Clean the blower motor housing to ensure adhesive strips on the back of the blower motor cover will stick (standard window cleaner can be used).
Note: Be sure to remove all residual film from the blower motor housing that may have been left by cleaning.
5. Peel the protective coverings from the adhesive strips on the blower motor cover. See Fig. 1.
6. Install the blower motor cover onto the motor bracket. See Fig. 2.
7. Reconnect the blower motor harness connector.
8. Reattach the instrument panel lower cover (if equipped).
9. Run the blower motor at low fan speed. Confirm that the blower motor is working properly and the noise is eliminated or reduced to an acceptable level.

Blower Case Cleaning:
1. Remove the blower motor unit from the blower case.
2. Remove all foreign material from the case.
3. Reinstall the blower motor unit.

Technical service bulletin courtesy of Mitchell 1.

For more information on Mitchell 1 products and services, automotive professionals can log onto the company’s website at www.mitchell1.com.

You May Also Like

Toyota, Lexus Offer Lower Emissions EV Charging Program

Toyota has entered into an agreement to provide health and environmental impact data to Toyota and Lexus customers.

Courtesy of The Buzz by David Sickels

Toyota Motor North America (Toyota) has recently entered into an agreement with WattTime, a company that develops clean energy data-driven insights, software, and tools, to provide certain health and environmental impact data to Toyota and Lexus customers with eligible vehicles and enable them to find ideal charging times to reduce emissions when charging at home.

Lexus and Toyota Camera Calibration (VIDEO)

Joe Keene discusses how to calibrate the camera on a 2021 Lexus UX where the camera was removed and reinstalled.

Autel Expands Presence in Asia, Australia

Autel expands in the Asia-Pacific region with new energy vehicle charging solutions for residential and commercial use.

Get To Know The Equipment and Tool Institute (ETI)

Executive director of ETI sits down with editor Nadine Battah to discuss ETI and the events it hosts.

Utilizing NVH Tools

Technology has been improving on NVH tools over the years.

Other Posts

Charging Ahead With EV Opportunities

New data shows there will be room for – and a need for – products for both incoming electric and ICE vehicles.

Streamlight Stinger Color-Rite Rechargeable Flashlight

TechShop Reveal provides a 360 product video highlighting the industry’s latest innovations.

Why Is This Brand New PS Pump So Noisy?

There are several questions which you should ask yourself in this scenario. This video is sponsored by Rislone.

DOE Puts $48M Toward Improving America’s Power Grid

This effort aims to better control grid power flow to avoid outages, which costs the economy $150 billion annually.